Six Santos workers in blue uniforms and white hard hats walking through a gas processing plant

SantosOil and gas

Santos: Turning Ball Valve Work Order History into Maintenance Improvement Priorities

Published 5 min read

Key facts

Organisation
Santos
Industry
Oil and gas
Asset class
Valve
Asset class type
Ball Valve
Asset boundary limits
As per ISO 14224
Population analysed
1,135 ball valve functional location IDs
Primary solution
Nexaan Work Order Analyser
Supporting tools
Nexaan Asset Library; PM Optimisation
Analysis
Classification and analysis of 3,126 historical work orders against the ball valve equipment hierarchy and FMEA data, supported by assessment of failures, maintenance task intervals and potential cost or risk savings

Summary of the project

How Nexaan analysed 3,126 historical work orders to identify recurring failure patterns, potential FMEA gaps and a reported ~$600K savings opportunity within one asset class.

The engineering objective

The project examined how Santos’ recorded asset failures aligned with its ball valve FMEA data.

The objective was to establish which components and failure mechanisms appeared repeatedly in the work order history, where the existing FMEA data did not adequately represent that history, and which findings warranted further engineering investigation.

Nexaan analysed 3,126 historical work orders, mapping work order descriptions, text and notes to the ball valve equipment hierarchy and associated FMEA data. The resulting analysis surfaced recurring component issues, potential gaps in the equipment hierarchy and FMEA data, and records requiring closer review.

Nexaan estimated ~$600K in potential savings associated with the opportunities identified. This represents an improvement opportunity rather than documented realised savings.

The approach: map maintenance narratives to the FMEA

The analysis used a ball valve equipment hierarchy and associated FMEA data comprising:

  • 18 maintainable items
  • 57 parts
  • 24 failure mechanisms
  • 59 causes

Work order descriptions and long text were mapped through four levels:

  1. Maintainable Item
  2. Part
  3. Failure Mechanism
  4. Cause

This structure allowed the analysis to group records by the affected component and its assigned failure mechanism, rather than relying solely on equipment names or keyword counts.

The output also included classification confidence, explanatory reasoning, potential FMEA gap flags and secondary matches. These provided a basis for reviewing the proposed mappings against the original maintenance narratives.

3,102 of the 3,126 work orders received classification outputs, representing 99.2% classification coverage. This figure measures coverage; the dataset also contained uncertain classifications requiring engineering review.

Finding 1: recurring patterns identified specific areas for investigation

The analysis reported the following leading component and failure mechanism combinations:

ComponentAssigned failure mechanismWork order count
Solenoid valveFailed to open127
Seat ringCorroded124
Seat ringLoose101
Position indicatorFailed to communicate96
Switching valveLeaking77
Limit switchMisaligned73
Connection flangeLeaking69

Scroll sideways to see every column.

The two leading seat ring patterns accounted for 225 work order classifications.

These results gave the review team defined component and mechanism combinations to investigate. For example, the concentration of seat ring corrosion and looseness provided a starting point for examining service conditions, repair history and the suitability of existing maintenance instructions.

The report also highlighted looseness and leakage across several components as priorities for reviewing fastening practices, sealing instructions and maintenance strategy.

The counts represent patterns in the classified work order dataset. They provide investigation priorities, rather than equipment failure rates or confirmed root causes.

Finding 2: the existing FMEA needed targeted review

Approximately 11% of classified records were flagged as potential FMEA gaps.

These flags identified work orders whose described condition or failure did not fit the existing FMEA data cleanly. They created a review set for subject matter experts to determine whether:

  • The proposed classification was technically appropriate.
  • The FMEA data needed an additional or more specific failure entry.
  • Component terminology needed refinement.
  • The work order lacked sufficient evidence for a failure classification.
  • The record described a maintenance activity rather than an observed failure.

This distinction matters when updating an FMEA. A flagged record can indicate a missing failure path, but it can also expose ambiguous work order text or a mismatch between the recorded activity and the FMEA data.

The analysis therefore supported a targeted review of the FMEA against field history, with engineering judgement determining which changes were justified.

Finding 3: a single work order could contain multiple failure details

1,273 work orders, or 40.7% of the dataset, received secondary failure mode matches.

These records were identified for further review because reducing each narrative to one classification could omit relevant information about associated components or additional failure conditions.

Reviewing the secondary matches provides a way to assess whether the additional detail represents a separate failure, a contributing condition or another aspect of the same maintenance event.

Finding 4: the work order narrative determined how much could be inferred

The report included a useful contrast between detailed and ambiguous records.

One actuator work order explicitly described significant water ingress into the actuator housing, together with a valve issue recurring after adjustment. Nexaan mapped it to:

  1. Actuator
  2. Housing
  3. Contaminated
  4. Moisture Ingress

The record named the affected component and described the condition, giving the reviewer a clear basis for assessing the classification.

Other records contained limited descriptions such as a valve failing to open or a component requiring replacement. Some documented function testing or preventive changeout without an observed failure.

These records required closer scrutiny because the text did not establish a specific failure mechanism or cause.

The analysis made this limitation visible through confidence scores and classification reasoning. It also identified a practical data quality opportunity: improving the detail captured in work order closeout narratives so future maintenance analysis has stronger evidence.

From analysis to maintenance review

The project produced defined priorities for further engineering work:

Review priorityIntended engineering use
Potential FMEA gapsAssess missing failure paths, terminology and FMEA coverage.
Uncertain classificationsVerify proposed mappings against the original records and available evidence
Secondary matchesAssess additional failure information within individual work orders
Recurring looseness and leakageReview relevant fastening, sealing and maintenance instructions
Repeated component patternsFocus investigation on the combinations most frequently represented in the dataset

Scroll sideways to see every column.

This gave reliability and maintenance teams a structured basis for deciding where to direct their review effort.

For asset leaders, the commercial opportunity was to connect these findings to specific improvement actions and their associated costs. For engineers, the immediate value was a traceable set of patterns and exceptions that could be assessed against the maintenance history.

The project outcome

Nexaan converted the historical ball valve work order dataset into:

  • Structured classification outputs for 3,102 records.
  • Ranked component and failure mechanism patterns.
  • Potential FMEA gaps for engineering review, linking credible failures and operating context to FMEA updates.
  • Secondary matches across 1,273 work orders.
  • Defined priorities for maintenance instruction and strategy review.

The project demonstrated how analysis of an existing asset class history can support FMEA refinement and maintenance improvement planning.

The estimated ~$600K potential savings opportunity provides commercial context. The documented analysis establishes the technical review priorities; confirmation of implemented changes and realised benefits requires the corresponding project outcome records.

Key questions

How many work orders were analysed in the Santos ball valve study?

Nexaan analysed 3,126 historical work orders, mapping work order descriptions, text and notes to the ball valve equipment hierarchy and associated FMEA data.

What does a potential FMEA gap flag show?

These flags identified work orders whose described condition or failure did not fit the existing FMEA data cleanly.

Can one work order contain more than one failure mode?

1,273 work orders, or 40.7% of the dataset, received secondary failure mode matches.

Do work order counts show equipment failure rates?

The counts represent patterns in the classified work order dataset. They provide investigation priorities, rather than equipment failure rates or confirmed root causes.

Is the estimated ~$600K within one asset class a realised saving?

Nexaan estimated ~$600K in potential savings associated with the opportunities identified. This represents an improvement opportunity rather than documented realised savings.

Assess one asset class against its maintenance history

Start with a critical asset class and its existing FMEA. Nexaan can help identify recurring patterns, potential FMEA gaps and the work orders that warrant closer engineering review.

Discuss an asset class assessment with Nexaan.

View all case studies